Shelter From the Storm

Mason Knowles and Roger Morrison, PE, RRC

SPF and the hurricanes of Florida

Before 2004, Florida enjoyed more than a decade free of the ravages and destruction of major hurricanes. Unfortunately, things changed drastically that summer when four major storms swept across the state. On August 13, Charley, a Category 4 hurricane packing 225-km/h (140-mph) winds, slammed into the Gulf Coast area around Punta Gorda, made its way through Orlando, and finally exited near Daytona Beach. Along the way, it destroyed buildings, tore off roofs, and caused related damage that will take years to repair. Before the state could catch its breath, Hurricane Frances (a Category 2 storm with 177-km/h [110-mph] winds) hit Palm Beach on September 3, exiting into the Gulf of Mexico near Tarpon Springs, and then re-entering the panhandle region close to Tallahassee. Three days later, Hurricane Ivan—the most wayward storm of all—struck near Pensacola, went up into Georgia, and exited into the Atlantic, before turning 180 degrees into the Gulf and returning to hit the coast again a week later. On September 26, the season’s final storm hit, as the Category 3 Hurricane Jean took essentially the same route as Frances—often destroying what its predecessor did not.

While the hurricanes were truly ferocious, they were also the best-documented storms in history. Dozens of investigative teams from organizations such as the Federal Emergency Management Agency (FEMA), Roofing Industry Committee On Weather Issues (RICOWI), and the National Roofing Contractors Association (NRCA) have provided insight into what materials and systems work—and which ones do not—when building hurricane-resistant structures.

Spray polyurethane foam protection roofing
One assembly noted for its durability in storms is SPF or spray polyurethane foam roofing system. Many such spray polyurethane foam roofs were able to survive unscathed or with minor surface damage. Steep sloped roofs where asphalt shingles or ceramic tiles had been covered with spray polyurethane foam roofing also fared well. In many cases where roofs were partially repaired with spray polyurethane foam roofing after Hurricane Frances, the foam was the only product remaining after Jean, a few weeks later.

Spray-applied as a liquid, spray polyurethane foam roofing reacts and expands in place to form a firmly adhered, rigid, seamless mass of closed-cell foam. Based on small-scale wind uplift testing, spray polyurethane foam roofing systems have achieved very high wind uplift ratings. Due to the adhesive, compressive, and tensile strength of spray polyurethane foam, the typical mode of failure in small-scale testing (i.e. 3.6 x 7.3-m [12 x 24-ft] panels) is the fastening of the deck (i.e. screw pullout). Testing over re-cover panels has suggested the added stiffness and reduced profile of spray polyurethane foam roofing increases the wind uplift resistance of an existing roof membrane. As a result, spray polyurethane foam roofing systems are frequently installed over existing roof membranes such as built-up roofs (BUR) or modified bitumen (mod-bit).

Investigating spray polyurethane foam roofing failures
Even with the added wind uplift resistance provided by spray polyurethane foam roofing, some failures were reported and documented. Understanding how and why these problems occurred not only can help specifiers select materials more appropriately, but can also provoke discussion on further design considerations for heavy wind-prone areas.

Deck
Roof decks provide the structural support for the waterproofing and insulating components of the roofing system. Commonly constructed of concrete, steel, or plywood, these decks can fail as a result of high-pressure differentials (also known as ‘pressurization’).

When wind encounters an obstruction such as a building, air pressure tends to increase on the windward side relative to the leeward side. As wind passes over a roof, the velocity increases because the air must travel a greater distance. As air velocity increases, its pressure tends to decrease (similar to air passing over an aircraft wing)—thus, the air pressure atop the roof tends to be lower than the underside. When a window or door fails, this effect is exacerbated as the pressure within the building suddenly—and catastrophically—spikes, blowing up large sections of roof deck and the roof membrane with it.

Substrate
When installed as a re-cover, spray polyurethane foam roofing is applied directly to an existing roof membrane. While testing and field performance indicates the foam tends to increase wind uplift resistance of the combined system, should the underlying substrate or roof membrane be insufficiently attached/adhered, the total roofing system can still be vulnerable to blow-off.
The typical mode of substrate failure was a loosening of the windward edge followed by a peel-back of the roofing membrane. Depending on the security of the underlying insulation, the roofing membrane peel-back can take the insulation boards with it. At some point in the peel-back process, the roof membrane typically ruptures, leaving the remaining substrate and spray polyurethane foam roofing intact.

Substrate failures can be due to insecure edges and insufficient adhesion or fastening of the roof membrane and insulation boards to the deck. Roofing membrane systems are highly dependent on the roof edge for their security, yet these edges are the most exposed detail on the roof. Furthermore, the pressure difference across the roof membrane tends to add extra uplift forces to the edge. Once the edge submits to these forces, a roofing membrane peel-back is almost inevitable.

Roof edges are usually fabricated from metal and fastened to a wooden roof edge nailer with screws, nails, and/or cleats. The security of the metal edge is dependent on its stiffness, the quality and quantity of fasteners, and the security of the nailer.

Surface damage
Surface damage of spray polyurethane foam roofs occurred due to the impact of wind-borne ‘missiles’ (such as tree limbs, broken tiles, and metal debris). Gravel scour occurred at windward roof corners and near roof protrusions and roof-mounted equipment in some cases. Little or no loss of waterproofing resulted from this damage due to the closed-cell properties of the spray polyurethane foam roofing.

General observations
Generally, spray polyurethane foamroofs performed very well during the 2004 hurricane season in Florida. Failures were limited to deck and substrate failures and while surface damage occurred, it was not a cause of failure or leakage.

Substrate failure could be minimized or eliminated by improving edge and roof membrane security when installing spray polyurethane foamroofs. Possible improvements include the following considerations:

Mason Knowles is the executive director of the Spray Polyurethane Foam Alliance (SPFA). He can be contacted by e-mail via masonknowles@sprayfoam.org.

Roger Morrison, PE, RRC, is a registered roof consultant with the Roof Consultants Institute (RCI) and has been active in the spray polyurethane foam industry for more than 20 years. Morrison participated in an investigation of roof damage following Hurricane Charley in August 2004. He can be contacted via e-mail at TK.